The user watchdog scan time has been exceeded. You may have to increase the Watchdog time, try 1ms.
The user watchdog scan time has been exceeded. Aug 1, 2007 · We have 2 robot welding cells in the rear of our plant that have just started getting Watchdog timeout faults on the SLC 5/05 CPU's. Apr 2, 2021 · Troubleshooting Tutorial: Common SLC 500 Faults – Part 2 : Processor Faults Programmable Logic Controllers (PLC) such as Allen-Bradley’s SLC 500 Modular or Fixed style hardware are designed with capability of self-diagnostics. But the Watchdog (S:3) is set to 10 x 10 = 100 milliseconds. Non-Recoverable • Determine if the program is caught in a loop and correct the problem. MrPLC. You may have to increase the Watchdog time, try 1ms. When I cleared the fault from the error screen, I immediately would get: "Error 187 - I/O configuration mismatch, check module 1. Has program been changed recently? Is 5/03 communicating with others? As I have seen a "WatchDog" bit programmed so if "Loss of Comms" occurs then processor faults. Jun 6, 2005 · At seemingly random times (about 1 or 2/week), I was getting: "Error 22 - The user watchdog scan time has been exceeded". Perform one of the following: • Determine if the program is caught in a loop and correct the problem. com Apr 15, 2005 · You can change the watch dog timer value in the controller status file, the number shown is times 10 so a value of 20 would have a watchdog value of 200ms. Jun 27, 2024 · This is a normal behavior. "0022: The User Watchdog scan time has been exceeded. So the problem is a firmware bug, or a hardware failure, or maybe a storm of network traffic that caused the controller to spend too much time on sorting out communications. Dec 26, 2018 · The maximum observed scan time (S:22) is 1. Mar 4, 2008 · This would, obviously, cause the watchdog timer to time out though. In order to prevent this I used an MVM on both the High and Low Byte of S:3 (the program scan word), checked the difference between the current program scan and watchdog time, and initiate a temporary end (TND) should the two values be within 2 ms of each other. Sep 11, 2003 · Go to S2 Status file "Scan times" this should show you the last scan time before faulting. 6 seconds, then either it's got some hellacious loops, somebody (or something like the Quickpanels) has been messing with the Status file, or there's a program corruption that was misinterpreted as a watchdog fault. 000 milliseconds, and the last scantime (S:35) was 0. With Self-diagnostics, the controller is able to detect the operational status of every member module and report this externally through varying behavior of built-in Jan 17, 2025 · How to change watchdog timeout value in the Micro800 controller? The program scan time exceeded the watchdog timeout value in the Micro800 controller. 400 milliseconds. Goodluck. The watchdog on the simulator is activated only to detect infinite loops. • In the user program, increase the watchdog timeout value that is set in the system variable _SYSVA_TCYWDG and then build and download the program using Connected Components May 8, 2003 · If this application requires a Watchdog time of 1. Simulator is running on your PC with numerous processes running at the same time. Forums - Forums. When running the simulator, the processor used is the one from the computer, which has many more services to deal with. • Increase the watchdog timeout value in the status file The program scan time exceeded the watchdog timeout value. Jun 12, 2017 · From the manual 0022 WATCHDOG TIMER EXPIRED, SEE S:3 The program scan time exceeded the watchdog timeout value (S:3H). In the processor under the Data Files S2 - Status, Scan Times, the following is labeled: Maximum = the E03901 Watchdog TimeoutE: 67 Hello, We have been getting E03901 errors on one of our P1000's on a periodic basis, which is causing a complete shutdown of the PLC into stop mode. .
Back to Top