Payne furnace code 33. the My Payne furnace had a 33 code and now has a 13 code.


Payne furnace code 33 The Furnace May Try Several Ignition Sequences Before Locking Out. My furnace wasn't staying lit for more than 2 minutes. 76K subscribers 5 I got a code 33 on payne furnace, yes, it is blinking 3 short and 3 the payne model is pg95XAT, i clean the electronic Sep 17, 2025 · Codes 33 (LIMIT CIRCUIT FAULT): These codes highlight a range of issues, from airflow and ignition problems to faults in the furnace’s control circuits, each requiring specific diagnostics and repairs. Some codes indicate issues you Dec 15, 2015 · I need your help regarding furnace error Code 33 for Carrier, Bryant and Payne systems. the My Payne furnace had a 33 code and now has a 13 code. It is adequately heating the house in this way. it started as a code 33 and after a few min went to 13. or until payne furnace codes The Payne gas furnace has built in diagnostics and is designed to assist with the identification and correction of faults. This guide provides clear, safe, step-by-step instructions for diagnosing and resetting Payne Payne Plus 80 furnace shuts off after about four minutes of heating, but runs properly if I remove the filters. Jan 30, 2024 · On Carrier, Bryant and Payne furnaces, the lack of airflow will cause an error 33, and sometimes lead to error 13 due to safety lockout. He Payne or Bryant furnace error code 33 how to properly troubleshoot. Aug 7, 2025 · Error codes are the best first clue to why a Payne furnace is not working properly. more I have a 5 year old Payne Furnace Model# PG92SBS48080BBAA - 80,000 BTU 5 Supply registers throughout first floor, One return - ample sizing I have consistently had a code 13 then 33 pull from this unit: 13: LIMIT CIRCUIT LOCKOUT: Lockout occurs if a limit or flame rollout switch is open longer than 3 minutes. The blower is running, but the burners are not on. Feb 5, 2024 · If you’re experiencing a Payne furnace error code 33, it indicates a limit circuit fault, specifically that the limit flame rollout switch is open. Understanding what Code 33 typically indicates helps homeowners diagnose safely and decide whether to attempt at-home fixes or call a professional. Then the flames would come on again for The Payne furnace Code 33 is a common diagnostic that can signal an ignition-related problem or a flame sensing issue. Troubleshooting with the blinking lights of a Payne furnace is easy. It's reporting code 33 and tripping the flame-out sensor. I have a Payne furnace with code 33. Jul 15, 2025 · What Does Payne Furnace Code 33 Mean? The Code 33 on a Payne furnace control board generally indicates a lockout due to a failed ignition sequence or flame sensing failure. Feb 10, 2023 · Payne Furnace troubleshooting guide is going to become a great help for you if you see the problem with your furnace. Understanding the code pattern and location is critical for fast troubleshooting. Jul 2, 2025 · Payne furnace error codes are diagnostic tools that help identify issues with the heating system. Aug 25, 2025 · For homeowners and technicians, recognizing and addressing this code quickly is essential for restoring efficient furnace operation. If open longer than 3 minutes, code changes to lockout #13. . Feb 13, 2016 · . If open less than 3 minutes status code #33 continues to flash until blower shuts off. Any input would be once again very much appreciated!! Ok, this is a high limit code. TJ HVAC Service and Install, LLC 2. This article provides a detailed explanation of Payne Furnace Code 33, its causes, diagnostic steps, and practical solutions. Now I'm getting code 33 5-6 minutes after the flame fires up. Currently Sep 9, 2025 · What Paynе Furnace Code 33 Means Payne furnaces Use Diagnostic Codes To Communicate Faults To The User. Because each model may map codes differently, the precise meaning should be verified in the owner’s manual or on the furnace’s data plate. If code 33 appears, the furnace may enter a lockout to prevent heat production until a safe restart is achieved. I have tried everything to troubleshoot Because Payne products span multiple series and control boards, the precise definition can differ from one unit to another. Contractor's Assistant: Are you planning to handle the repairs yourself? Customer: If I can. Jul 2, 2025 · Payne furnaces are reliable heating systems with specific components and model variations. Oct 23, 2025 · This article provides an in-depth, practical guide for American homeowners on understanding Payne furnace code 33, performing a safe reset, and identifying when professional help is needed. Knowing the key parts and how to identify your model will help with maintenance and troubleshooting. Jan 25, 2024 · Bryant furnace code 33 (3 short flashes and 3 long flashes) indicate a limit circuit fault – this means that the high limit switch has been open. Dec 15, 2021 · Most high-efficiency furnaces include internal diagnostic systems that signal system problems with flashing codes that correspond to the problem. 7 years. First code I found was 34 which I fixed by replacing the flame sensor. With the filters installed it throws a code 33, the blower runs for a couple minutes, then the code goes away and the furnace starts up again, and the cycle begins anew. The blower would continue to blow cold air for 4 minutes. Contractor's Assistant: Is Payne furnace gets code 33 (limit circuit fault) and short cycles, but doesnt when the filter is removed. This can be viewed through a port on the blower access panel. 33 LIMIT CIRCUIT FAULT – Indicates the limit, flame rollout is open. I've replaced the sensor and same issue. Learn how to quickly identify issues, perform essential checks, and when to seek professional help. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset. 6K views 2 replies 3 participants last post by Doc Holliday Nov 10, 2011 J Discover more answers I am getting a code 13 on a payne pg9maa series f furnace. Feb 11, 2024 · Payne Furnace troubleshooting: To troubleshoot a Payne furnace, start by checking if the filter is clean and the thermostat settings are correct. The furnace utilizes an LED, to describe its condition. If it will not reset by turning off the power then back on, then you may have a flame rollout limit that needs to be manually reset, or the auto reset limit is stuck open. While a simple reset can clear transient issues, persistent Code 33 indicates an underlying problem that may require professional service. I plan to consult with another HVAC company, but I would be interested to hear your thoughts on what you think might be going on. Nov 8, 2024 · Struggling with your Payne furnace displaying code 33? This article guides you through common issues and troubleshooting tips to restore your heating system's performance. Sep 14, 2025 · Payne Furnace Error Code 33 Signals A Fault That Requires Diagnosis. This Guide Explains Common Meanings, Step-By-Step Troubleshooting, Safety Precautions, Maintenance Tips, And When To Call A Professional To Resolve Code 33 Quickly And Safely. Oct 22, 2025 · In Payne furnaces, Code 33 generally represents a fault related to ignition, flame sensing, or a safety interlock such as a limit switch or pressure switch. If the switch remains open for more than 3 minutes, the code changes to lockout #7. Powering … Nov 9, 2011 · Carrier/ Payne FAU Gas lockout, codes 31, 33 and 13 Jump to Latest 4. The fan was running constantly, but the air was cold. Nov 12, 2024 · Struggling with your Payne furnace this winter? Our comprehensive guide on troubleshooting codes provides you with essential insights into error messages like Code 14, Code 33, and more. The trouble codes were 33 which becomes 13 after a period of time. CODE: RED LED1 ON. Code 33 on a Carrier furnace means the limit or flame rollout switch is open. 1. Payne Furnace [NG] triggering code 33. Customer: I have a Payne furnace that was functioning well until we experienced high winds, which caused the power to go on and off. Dec 10, 2022 · Learn what a carrier furnace error code 33 means and how to reset it when you've resolved the issue. What could be the issue? Contractor's Assistant: Have you checked the filters of the furnace? Customer: Yes. Code 33 on a Payne furnace signals a fault in the ignition or flame sensing system and typically triggers a safety lockout to prevent heat from circulating. I have a Payne furnace. Apr 4, 2024 · Struggling with a payne furnace code 33 reset? Our guide offers simple solutions to fix your Payne furnace error and restore warmth to your home. Dec 3, 2019 · Our comprehensive Payne Furnace error code guide will explain common issues, provide tips, and show you how to read your model's error codes. Ensure the gas line is turned on and the pilot light is functioning properly. Check for: – Restricted vent – Proper vent sizing – Loose blower wheel – Excessive wind – Dirty filter or restricted duct system. These codes typically appear as flashing lights on the furnace control board or display panel. Mar 1, 2016 · Payne Plus 80 furnace shuts off after about four minutes of heating, but runs properly if I remove the filters. I will post a picture of the manual reset rollout if you need to know what they look like. The furnace attempts several ignition trials; if it cannot detect a flame by the sensor within a set time, it enters a lockout mode to prevent unsafe conditions such as unburned gas accumulation. I am getting code 13, then 33 on my Payne gas furnace. Feb 21, 2019 · These new parts had no effect in terms of this issue and the furnace is still throwing code# 33. (See code 33) Then Code 33 pulls: LIMIT CIRCUIT FAULT: Indicates a Limit or Flame I'm trying to track down why my Payne PG95SAS is giving me a code 33. Once the sensor is reset it will reboot and run again until it trips sensor again (3-5 hours). Have an approximately 15 year old natural gas furnace. This error can cause the blower to run for 4 minutes or until the switch remakes, whichever is longer. Flame Rollout switch and BVSS require manual reset. If longer than 3 minutes, code changes to lockout #13. About a week. How does this site work and how much to trouble shoot? Just changed with new, Yes, Jan 30, 2009 · Recently, my Pane PG8DAA downflow furnace stopped delivering heat. I was receiving the Code 33 "limit switch" error code and I had a HVAC guy troubleshoot. Blower will run for 4 min. Now it's displaying a code 3 3. It's been installed and worked perfect for around 5 years and just stopped heating. Error 33 is a Limit Circuit Fault. Aug 19, 2021 · If you're having trouble with your furnace, understanding the Payne furnace error codes can help you zero in on the problem quickly. But keep your owner's manual handy. It means that it describes all the possible problems in detail and helps you to deal with them effectively. You can take corrective action in response to any faults indicated by the LED. Code 33 Typically Indicates An Ignition Or Flame Sensing Fault Where The Control Board Detects No Valid Flame After Attempting To Light The Burner. cwzhx mzzgoq ey65x cvxyi2 zzap8pz nnvw vvm qz2 xld fexdd